Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Journal of Bioactive and Compatible Polymers
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Nagaoka, S.
Right arrow Articles by Akashi, R.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Low Friction Hydrophilic Surface for Medical Devices

Shoji Nagaoka

Basic Research Laboratories Toray Industries, Inc. 1111 Tebiro, Kamakura Kanagawa, 248 Japan

Ryojiro Akashi

Basic Research Laboratories Toray Industries, Inc. 1111 Tebiro, Kamakura Kanagawa, 248 Japan

A hydrophilic polymer surface with low friction has been devel oped. A coating can be attached by the reaction of an epoxy containing poly (vinyl pyrrolidone) with the polyamino compound formed on the surface of the substrate. The epoxy containing poly(vinyl pyrrolidone) was obtained by the copolymerization of vinyl pyrrolidone, glycidyl acrylate, and vinyl acetate. A molecular weight of 400,000 or more is essential to achieve low surface friction. Polyurethane catheters in rabbit models, both with and without the hydro philic low friction coating, were evaluated for surface friction coefficient and blood compatibility. The coated catheters produced no lesions of the intima of the blood vessels and no thrombus formation on the catheter surface, while the non-coated catheters injured the intima of the blood vessels and severe throm bus formation was found on their surfaces.

Journal of Bioactive and Compatible Polymers, Vol. 5, No. 2, 212-226 (1990)
DOI: 10.1177/088391159000500205


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?