Journal of Bioactive and Compatible Polymers

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Register here to gain access to SAGE's 500+ Journals Online

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via ISI Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Demirkilic, U.
Right arrow Articles by Ayhan, H.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Journal of Bioactive and Compatible Polymers, Vol. 19, No. 5, 395-408 (2004)
DOI: 10.1177/0883911504046690

Investigation of Blood Compatibility and Determination of Clinical Performance of PMEA Coated and Flow Optimized Oxygenator

U. Demirkilic

E. Kuralay

H. Tatar

Gulhane Military Medical Academy, Cardiovascular Surgery Department, Etlik, Ankara, Turkey

M. Kocakulak

Ba\#351;kent University, Biomedical Engineering Department,Ankara, Turkey

C. Kocum

Hacettepe University, Faculty of Engineering, Chemical Engineering Department; and Institute of Pure and Applied Science, Bioengineering Division, Beytepe, Ankara, Turkey

H. Ayhan

Hacettepe University, Faculty of Engineering, Chemical Engineering Department; and Institute of Pure and Applied Science, Bioengineering Division, Beytepe, Ankara, Turkeyhayhan{at}hacettepe.edu.tr

In this study, the blood compatibility of the tip-to-tip coated and flow-optimized extracorporeal circuits were investigated using poly(2-methoxyethylacrylate) PMEA-coated oxygenators and tubing sets. Total protein, human serum albumin, fibrinogen, erythrocyte, leukocyte and platelets loss quantities were analyzed on blood samples withdrawn five different times during cardiopulmonary bypass (CPB) such as: baseline (T1), during CPB (T2), end of CPB (T3), after protamine injection (T4) and intensive care (T5), no fibrinogen loss was observed for the tip-to-tip coated system. After an operation, protein desorption assays from fiber surfaces of the tip-to-tip coated and flow-optimized extracorporeal circuits showed very little desorption. Less protein desorption was found between sonicated fibers and fiber sample solutions at <0.2mg/dL and 0.58mg/dL, respectively. For tip-to-tip coated and flow-optimized extracorporeal system, no platelet aggregation and no erythrocyte, leukocyte losses were observed. Optimized flow path and eliminated straight turns due to integration of exchangers minimized turbulent flows. Larger surface areas of the fibers optimized blood flow speed and improved gentle flow conditions and lowered shear stress. Clinically, no excessive postoperative bleeding was observed by the patients with the tip-to-tip coated system after 24 hours (hemorrhage was 387mL). The average unit of red blood cell and fresh frozen plasma transfusions were 0.98 and 2.10 units, respectively. Differences in adsorbed HSA on the hollow fiber surfaces were examined by STM which indicated that less protein existed on the sample solution of the non-sonicated fiber surfaces.

Key Words: oxygenator • extracorporeal circuits • fibers • HSA adhesions • STM imaging


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?