Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Journal of Bioactive and Compatible Polymers
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Ward, C. M.
Right arrow Articles by Seymour, L. W
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

A Sensitive Assay System for the Determination of Poly(L-Lysine) Concentration Using Turbidometry

Christopher M. Ward

CRC Institute for Cancer Studies, University of Birmingham, Birmingham B15 2TA, UK

Kerry D. Fisher

CRC Institute for Cancer Studies, University of Birmingham, Birmingham B15 2TA, UK

Leonard W Seymour

CRC Institute for Cancer Studies, University of Birmingham, Birmingham B15 2TA, UK

The titration of albumin into poly(l-lysine) (pLL) dissolved in HEPES buffer (50 mM, pH 7.5) leads to a maximum turbidity that is directly proportional to the pLL concentration. This technique provides an accurate and precise determination of unknown pLL concentrations. Turbidity of albumin/pLL is decreased at high concentrations of salt and high pHs, suggesting that the albumin/pLL interaction has an electrostatic component. A standard ratio of albumin to pLL is required to attain maximum turbidity which is independent of pLL concentration. Increasing salt concentration or increasing pH decreases the albuminlpLL ratio required to attain maximum turbidity. An apparent association of log10 molecular weight with turbidity could provide a method to determine pLL molecular weights. A comparison of this method with two commercially available protein assays and size exclusion Catsec HPLC analysis revealed the turbidometric method to have the best correlation (R = 1.0) and the lowest detection limits (0.05 µg/mL limit of detection). This turbidometric analysis can also be used for the determination of polyethyleneimine concentrations (R = 1.0) and, possibly, other cationic polymers.

Journal of Bioactive and Compatible Polymers, Vol. 14, No. 2, 122-136 (1999)
DOI: 10.1177/088391159901400202


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?